# BS 7273-4: releasing locked doors when the fire alarm sounds, explained

Reviewed by the SPS Technical team · Last checked 12 October 2026

## Quick answer

BS 7273-4 is the British Standard for how a fire alarm should release doors that are locked by access control or held open by magnetic devices. It sorts doors into categories A, B and C by how critical they are to escape, and sets how reliable the link between the fire alarm and the door must be. The current edition is BS 7273-4:2015+A1:2021.

## What it means for you

- Any access-controlled door on an escape route should release automatically when the fire alarm operates.
- Ask your fire risk assessor which category each controlled door falls into.
- Test the door release as part of the fire alarm service, not just the access control service.
- Keep a green break-glass or other manual release at controlled exit doors where required.

## Who it applies to

Any building where doors are locked by access control, held open by door holders or controlled by automatic door systems, and the fire alarm needs to release them.

## Common questions

Do access-controlled doors have to open in a fire?

Doors on escape routes must let people out. BS 7273-4 sets out how the fire alarm should release them and how dependable that connection needs to be.

What are categories A, B and C?

They grade how critical the door is to safe escape. Category A is the most critical and needs the most reliable link to the fire alarm; categories B and C allow simpler arrangements.

## Official sources

- Search BSI Knowledge: https://knowledge.bsigroup.com/search?query=BS%207273-4

This page is a plain-English summary, not a copy of the standard. British Standards are copyright of BSI.

## Page updates

- 12 October 2026: Edition confirmed as BS 7273-4:2015+A1:2021.

Reviewed by the SPS Technical team · Last updated October 2026

## Structured data

```json
[
  {
    "@context": "https://schema.org",
    "@id": "https://sps-technical.com/#organization",
    "@type": "Organization",
    "name": "SPS Technical",
    "legalName": "SPS Security Ltd",
    "parentOrganization": {
      "@id": "https://sps-security.com/#organization"
    },
    "description": "SPS Technical is the fire and security systems division of SPS Security Ltd, providing commercial fire alarm, CCTV, intruder alarm and access control design, installation, maintenance, monitoring and system takeovers across Yorkshire, Lincolnshire and the Humber.",
    "url": "https://sps-technical.com",
    "logo": "https://media.base44.com/images/public/6989f2350e53aab8836435e3/0ceea3d11_SPSTECHNICALLOGO.jpg",
    "telephone": "+441482226570",
    "email": "info@sps-technical.com",
    "foundingDate": "1992",
    "address": {
      "@type": "PostalAddress",
      "streetAddress": "Neptune House, Neptune Street",
      "addressLocality": "Hull",
      "addressRegion": "East Yorkshire",
      "postalCode": "HU3 2BP",
      "addressCountry": "GB"
    },
    "hasCredential": [
      {
        "@type": "EducationalOccupationalCredential",
        "name": "SSAIB registration HUMB018: intruder alarms (PD 6662), CCTV (SSAIB Code of Practice SS2003), access control (SSAIB Code of Practice SS2002) and fire alarm systems",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "SSAIB",
          "url": "https://www.ssaib.org"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "BAFE SP203-1 certificate 104302 (BAFE organisation ID 303286): fire detection and alarm system design, installation, commissioning and maintenance",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "BAFE",
          "url": "https://www.bafe.org.uk"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "ISO 9001:2015 certificate 1208-QMS-001",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "Alcumus ISOQAR"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "ISO 14001:2015 certificate 1208-EMS-001",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "Alcumus ISOQAR"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "CHAS membership CHAS-0004703",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "CHAS"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "Constructionline Bronze registration 92018",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "Constructionline"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "SafeContractor certificate PE5040",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "Alcumus SafeContractor"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "Paxton Gold Installer",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "Paxton"
        }
      },
      {
        "@type": "EducationalOccupationalCredential",
        "name": "Approved installer of police-response intruder alarms: Humberside Police, Lincolnshire Police, North Yorkshire Police, South Yorkshire Police, West Yorkshire Police, Nottinghamshire Police, Derbyshire Constabulary, Greater Manchester Police",
        "credentialCategory": "certification",
        "recognizedBy": {
          "@type": "Organization",
          "name": "UK police forces (NPCC Police Requirements for Security Systems)"
        }
      }
    ],
    "areaServed": [
      {
        "@type": "AdministrativeArea",
        "name": "East Yorkshire"
      },
      {
        "@type": "AdministrativeArea",
        "name": "North Lincolnshire"
      },
      {
        "@type": "AdministrativeArea",
        "name": "Lincolnshire"
      },
      {
        "@type": "AdministrativeArea",
        "name": "South Yorkshire"
      },
      {
        "@type": "AdministrativeArea",
        "name": "West Yorkshire"
      },
      {
        "@type": "AdministrativeArea",
        "name": "North Yorkshire"
      }
    ],
    "knowsAbout": [
      "Fire alarm systems",
      "CCTV systems",
      "Intruder alarm systems",
      "Access control systems",
      "System monitoring",
      "Planned preventative maintenance",
      "Fire and security system takeovers",
      "Multi-site fire and security maintenance",
      "Maintenance and compliance"
    ]
  },
  {
    "@context": "https://schema.org",
    "@type": "BreadcrumbList",
    "itemListElement": [
      {
        "@type": "ListItem",
        "position": 1,
        "name": "Home",
        "item": "https://sps-technical.com/"
      },
      {
        "@type": "ListItem",
        "position": 2,
        "name": "Resources",
        "item": "https://sps-technical.com/resources"
      },
      {
        "@type": "ListItem",
        "position": 3,
        "name": "BS 7273-4:2015+A1:2021"
      }
    ]
  },
  {
    "@context": "https://schema.org",
    "@type": "Article",
    "@id": "https://sps-technical.com/resources/standards/bs-7273-4#article",
    "headline": "BS 7273-4: releasing locked doors when the fire alarm sounds, explained",
    "description": "BS 7273-4 is the British Standard for how a fire alarm should release doors that are locked by access control or held open by magnetic devices. It sorts…",
    "url": "https://sps-technical.com/resources/standards/bs-7273-4",
    "mainEntityOfPage": "https://sps-technical.com/resources/standards/bs-7273-4",
    "inLanguage": "en-GB",
    "dateModified": "2026-10-12",
    "author": {
      "@id": "https://sps-technical.com/#organization"
    },
    "publisher": {
      "@id": "https://sps-technical.com/#organization"
    },
    "about": {
      "@type": "DefinedTerm",
      "name": "BS 7273-4:2015+A1:2021",
      "description": "Code of practice for the operation of fire protection measures: actuation of release mechanisms for doors",
      "url": "https://knowledge.bsigroup.com/search?query=BS%207273-4"
    },
    "citation": "https://knowledge.bsigroup.com/search?query=BS%207273-4"
  },
  {
    "@context": "https://schema.org",
    "@type": "FAQPage",
    "mainEntity": [
      {
        "@type": "Question",
        "name": "Do access-controlled doors have to open in a fire?",
        "acceptedAnswer": {
          "@type": "Answer",
          "text": "Doors on escape routes must let people out. BS 7273-4 sets out how the fire alarm should release them and how dependable that connection needs to be."
        }
      },
      {
        "@type": "Question",
        "name": "What are categories A, B and C?",
        "acceptedAnswer": {
          "@type": "Answer",
          "text": "They grade how critical the door is to safe escape. Category A is the most critical and needs the most reliable link to the fire alarm; categories B and C allow simpler arrangements."
        }
      }
    ]
  }
]
```